47
© 2008 Directed Electronics. All rights reserved.
Shutdown diagnostics
To perform shutdown diagnostics:
With the ignition OFF, press and hold the Program switch.1.
Turn the ignition ON and then back OFF while holding the Program 2.
switch.
Release the Program switch.3.
Press and release the Program switch. The LED reports the last shutdown 4.
for one minute or until the ignition is turned on, as shown in the following
table:
LED Flashes Shutdown Mode
1 Timed out
2 Over-rev shutdown
3 Low or no RPM
4 Transmitter shutdown (or optional push button)
5 (-) Shutdown (H3/4 GRAY) or (+) Shutdown (H3/3
BROWN)
6 (+) Brake shutdown
7 (-) Neutral safety shutdown (H3/1 BLACK/WHITE)